Versatile Autosamplers with Sampling Flexibility
AS-2050/AS-2051 Autosampler
Fully automatic sample injection systems with excellent productivity and the highest possible level of precision - Fixed loop or variable volume injection modes
- Reproducibility better than 0.2% RSD using 20 μL fixed loop injection mode with less than 0.01% sample contamination. With variable 10 μL injection mode, the RSD is better than 0.3%
- 100 samples with 2 mL vials standard
182 samples with 0.6 and 0.3 mL vials
192 samples with two 96-well microplates
768 samples with two 384-well microplates - 5 operating modes; normal, two methods of pre-column derivatization, dilution, and zero-sample loss injections in stand-alone mode
- Injection volume from 0.1 μL to 200 μL (standard), 1 ~ 2000 μL (optional)
- Cooling and heating capability (AS-2051 only)
Click here to view the AS-2050/2051 autosampler specifications.
AS-2055/2057 Autosampler Compact automatic sample injection systems only 15 cm wide
JASCO Models AS-2055/2057 are fully automatic sample injection systems
enabling greater productivity and the highest possible level of
precision
- 50 samples with 2 mL vials standard
84 samples with 0.6 and 0.3 mL vials
96-well or 384-well microplate - Cooling and heating capability (AS-2057 only)
- Biocompatible models using PEEK (AS-2055i/2057i)
Click here to view the AS-2055/2057 autosampler specifications.
AS-2059 Autosampler Unparalleled sampling flexibility with up to 768 well positions (two 384-well microplates) as an option for laboratory automation and combinatorial chemistry.
The JASCO Model AS-2059 autosampler is a fully automatic sample
injection system enabling greater productivity and the highest possible
level of precision. Sampling flexibility is unparalleled with up to 768
well positions (two 384-wells microplates) as an option for laboratory
automation and combinatorial chemistry.
- Variable sample volume injection method (Zero Sample Loss)
- Reproducibility less than 0.2% RSD for 5.1 to 100 μL injection
- Less than 0.002% sample contamination for 10 μL injections
- 120 samples with 2 mL vials standard
224 samples with 0.6 and 0.3 mL vials
192 samples with two 96-well microplates
768 samples with two 384-well microplates
- Random sample access is provided as well as random number of injections and random injection volume for each vial
- Optional Peltier cooling and heating unit (TC-2059)
- Automatic recognition of sample rack
Click here to view the AS-2059 autosampler specifications.